ATC Diversified 1-Phase Under/Over Voltage Monitor, 8-Pin Socket Mount, 12 VDC, VBA-12-DLA

Item No.58073
Product Details Widely used in the water and wastewater industry to keep control panels operating properly Use to protect 1-phase equipment from damaging under/over voltage conditions The VBA Series offers protection to single phase equipment that is required to operate between two voltage limits. S
Price $430.95
price per each
excl. tax
In Stock

Description

Product Details
  • Widely used in the water and wastewater industry to keep control panels operating properly
  • Use to protect 1-phase equipment from damaging under/over voltage conditions

The VBA Series offers protection to single phase equipment that is required to operate between two voltage limits. Supply voltage is monitored for a preselected UNDER and OVER voltage limit. With normal operating voltage applied, the internal relay will energize (PICK-UP). When the voltage falls outside the preset Over/Under trip points for longer than the release delay, the relay will de-energize (DROP-OUT). When line conditions return to normal, the VBA Series automatically resets and the internal relay energizes. The HYSTERESIS in each unit on the Under and Over limits provides a differential between the PICK-UP and DROP-OUT trip points.

Product Information

Item number
58073
Brand Name
ATC-Diversified
Catalog Page
287
Net weight
0.5
Condition
New

ATC Diversified 1-Phase Under/Over Voltage Monitor, 8-Pin Socket Mount, 12 VDC, VBA-12-DLA

Item number
58073
Brand Name
ATC-Diversified
Catalog Page
287
Net weight
0.5
Condition
New
Price $430.95
price per each
excl. tax
In Stock
each
Need Help? Call 800-548-1234
Product Details
  • Widely used in the water and wastewater industry to keep control panels operating properly
  • Use to protect 1-phase equipment from damaging under/over voltage conditions

The VBA Series offers protection to single phase equipment that is required to operate between two voltage limits. Supply voltage is monitored for a preselected UNDER and OVER voltage limit. With normal operating voltage applied, the internal relay will energize (PICK-UP). When the voltage falls outside the preset Over/Under trip points for longer than the release delay, the relay will de-energize (DROP-OUT). When line conditions return to normal, the VBA Series automatically resets and the internal relay energizes. The HYSTERESIS in each unit on the Under and Over limits provides a differential between the PICK-UP and DROP-OUT trip points.