Endress+Hauser COM 223 Dissolved Oxygen Transmitter (Panel Mount), COM 223-DX1105
Description
- Continuously monitors DO levels in your aeration tanks, lagoons and effluent
- Alarm contact and separate 4-20 mA output signals for DO and temperature values
The Endress+Hauser COM 223 dissolved oxygen transmitters continuously monitor DO levels in your aeration tanks, lagoons and effluent stream. Simple one-point calibration in air (100% saturation) or Winkler calibration value can be used. A user-friendly display makes the initial programming set-up and operation simple and intuitive.
The isolated 4-20 mA output signals can be scaled for DO concentration and temperature for recording/reporting purposes. The 4-20 mA signals are galvanically isolated, eliminating potential ground loop problems. A separate alarm contact can alert you to possible dissolved oxygen problems. Models are available with optional HART®, PROFIBUS® PA or PROFIBUS DP output communications. Contact USABlueBook for more information.
COM 223 DO transmitter is in a 1/4 DIN housing for mounting in an existing control panel. This panel-mount unit includes tensioning screws for easy mounting in a NEMA 4X enclosure.
Order sensor separately.
- Range: 0.00 to 20.00 ppm, (mg/L)
- Accuracy: ±0.5% of measuring range with COS 41 sensor
- Resolution: 0.01 ppm (mg/L)
- Analog outputs: (2) isolated 0-20 or 4-20 mA
- Alarm relay: 1 SPDT rated 2A @ 250 VAC
Product Information
- Item number
- 64010
- Brand Name
- Endress and Hauser
- Catalog Page
- 1110
- Net weight
- 2.2
- Condition
- New
Endress+Hauser COM 223 Dissolved Oxygen Transmitter (Panel Mount), COM 223-DX1105
- Item number
- 64010
- Brand Name
- Endress and Hauser
- Catalog Page
- 1110
- Net weight
- 2.2
- Condition
- New
- Continuously monitors DO levels in your aeration tanks, lagoons and effluent
- Alarm contact and separate 4-20 mA output signals for DO and temperature values
The Endress+Hauser COM 223 dissolved oxygen transmitters continuously monitor DO levels in your aeration tanks, lagoons and effluent stream. Simple one-point calibration in air (100% saturation) or Winkler calibration value can be used. A user-friendly display makes the initial programming set-up and operation simple and intuitive.
The isolated 4-20 mA output signals can be scaled for DO concentration and temperature for recording/reporting purposes. The 4-20 mA signals are galvanically isolated, eliminating potential ground loop problems. A separate alarm contact can alert you to possible dissolved oxygen problems. Models are available with optional HART®, PROFIBUS® PA or PROFIBUS DP output communications. Contact USABlueBook for more information.
COM 223 DO transmitter is in a 1/4 DIN housing for mounting in an existing control panel. This panel-mount unit includes tensioning screws for easy mounting in a NEMA 4X enclosure.
Order sensor separately.
- Range: 0.00 to 20.00 ppm, (mg/L)
- Accuracy: ±0.5% of measuring range with COS 41 sensor
- Resolution: 0.01 ppm (mg/L)
- Analog outputs: (2) isolated 0-20 or 4-20 mA
- Alarm relay: 1 SPDT rated 2A @ 250 VAC