GF Signet 9900 Transmitter; Field Mount, DC Powered, 3-9900-1
Description
Signet's 9900 universal-input transmitters provide a single-channel interface for a wide variety of parameters including pH/ORP, conductivity/resistivity, salinity, flow, pressure, temperature and level. Even 3rd party generic 4-20mA sensor signals can be displayed with the use of i-Go signal converter (sold separately). The large, auto-sensing display is readable at 4 to 5 times the distance of traditional transmitter displays, reducing the risk of misreading values.
The single-channel 9900 transmitter features a backlit display with separate lines for units as well as main and secondary measurements, plus a dial-type digital bar graph. It features two options for easy setup programming: simple full text-based menu via front panel buttons, or PC COMM Configuration software. Software option lets you customize labeling, min/max dial settings, and unit/decimal measurement choices using a Windows PC and the included USB connection tool. Optional plug-in modules let you easily adapt your transmitter to meet changing needs. Modules include relay (2 dry contact relays for panel-mount only), additional analog output, and H COMM (HART® Communication).
Field-mount transmitters requires purchase of a separate mounting kit. Choose from Universal Mounting Kit (stock # 26733) for mounting on a pipe or flat surface, or the Direct-Mount Kit and Angle Adjustment/ Spacer (stock # 10497 and 10497). This allows you to directly mount your transmitter to your digital sensor.
For a complete system, order:
1. Transmitter
2. Flow sensor
3. Sensor installation fittings: for inline flow-through applications
4. Mounting kit (for field mounting) or enclosure (for panel mounting)
- Input types: Digital: S3L (serial ASCII, TTL, 9600 bps); Frequency: 0.5 to 1500 Hz; accuracy 0.5% of reading
- Range: 0.00 to 15.00 pH; -1999 to 1999.9 mV; -9999 to 99,999 units per second, minute, hour or day (flow rate); 0.000 to 99,999 µS, mS, ppm, ppb, kO, MO (conductivity, TDS, resistivity)
- Outputs: Analog: standard (1) passive 4-20 mA in base unit; optional (1) additional via module (sold separately); Relay: optional (2) dry contacts via module (sold separately), 5A max; Open Collector: standard (1) in base unit, max 30 VDC
- Operating conditions: 14 to 158°F
- Power: Loop or 10.8 to 35.2 VDC (24 VDC nominal)
Product Information
- Item number
- 10492
- Brand Name
- GF Signet
- Catalog Page
- 1129
- Net weight
- 1.4
- Condition
- New
Accessories
Related
GF Signet 9900 Transmitter; Field Mount, DC Powered, 3-9900-1
- Item number
- 10492
- Brand Name
- GF Signet
- Catalog Page
- 1129
- Net weight
- 1.4
- Condition
- New
Signet's 9900 universal-input transmitters provide a single-channel interface for a wide variety of parameters including pH/ORP, conductivity/resistivity, salinity, flow, pressure, temperature and level. Even 3rd party generic 4-20mA sensor signals can be displayed with the use of i-Go signal converter (sold separately). The large, auto-sensing display is readable at 4 to 5 times the distance of traditional transmitter displays, reducing the risk of misreading values.
The single-channel 9900 transmitter features a backlit display with separate lines for units as well as main and secondary measurements, plus a dial-type digital bar graph. It features two options for easy setup programming: simple full text-based menu via front panel buttons, or PC COMM Configuration software. Software option lets you customize labeling, min/max dial settings, and unit/decimal measurement choices using a Windows PC and the included USB connection tool. Optional plug-in modules let you easily adapt your transmitter to meet changing needs. Modules include relay (2 dry contact relays for panel-mount only), additional analog output, and H COMM (HART® Communication).
Field-mount transmitters requires purchase of a separate mounting kit. Choose from Universal Mounting Kit (stock # 26733) for mounting on a pipe or flat surface, or the Direct-Mount Kit and Angle Adjustment/ Spacer (stock # 10497 and 10497). This allows you to directly mount your transmitter to your digital sensor.
For a complete system, order:
1. Transmitter
2. Flow sensor
3. Sensor installation fittings: for inline flow-through applications
4. Mounting kit (for field mounting) or enclosure (for panel mounting)
- Input types: Digital: S3L (serial ASCII, TTL, 9600 bps); Frequency: 0.5 to 1500 Hz; accuracy 0.5% of reading
- Range: 0.00 to 15.00 pH; -1999 to 1999.9 mV; -9999 to 99,999 units per second, minute, hour or day (flow rate); 0.000 to 99,999 µS, mS, ppm, ppb, kO, MO (conductivity, TDS, resistivity)
- Outputs: Analog: standard (1) passive 4-20 mA in base unit; optional (1) additional via module (sold separately); Relay: optional (2) dry contacts via module (sold separately), 5A max; Open Collector: standard (1) in base unit, max 30 VDC
- Operating conditions: 14 to 158°F
- Power: Loop or 10.8 to 35.2 VDC (24 VDC nominal)