Match Online Measurements with Those in the Lab Match Online Measurements with Those in the Lab
All Hach TU5 Series® Turbidimeters Use Identical Optics
Share results and samples seamlessly between the plant and the lab. All TU5 turbidimeters feature patented optical 360° x 90° Detection® for maximum accuracy.
Hach TU5300sc & TU5400sc Online Laser Turbidimeters
Shown as a complete system
Shown as a complete system
(from left to right: maintenance bracket, turbidimeter and controller)
Hach TU5300sc & TU5400sc Online Laser Turbidimeters
• Patented optical 360° x 90° Detection for maximum accuracy and repeatability
• Small sample volume delivers immediate readings and allows faster cleaning
• RFID-enabled turbidimeters allow quick, easy data transfer
These turbidimeters deliver outstanding low-level precision and sensitivity. Patented optical 360° x 90° Detection captures 90º scatter through 360º of detection for maximum accuracy. Meters deliver immediate readings, thanks to their small sample surface chamber volume up to 98% smaller than other meters. This also makes cleaning much easier.
Sensors track internal temperature and humidity, alerting you to condensation issues. They use quick-replacement sealed vials for easy calibration. An active drying system with desiccant cartridge and air pump circulates dried air throughout the sample cell compartment.
Choose from TU5300sc low-range models or TU5400sc ultra-high precision models with increased repeatability. Both offer exceptional performance in drinking water and other high-purity water applications. For added convenience and prevention of manual errors, choose RFID-enabled turbidimeters. Simply add RFID tags to your samples to store data and transfer information between RFID-capable TU5 instruments, including benchtop turbidimeters. These units also feature Internal System Check, which automatically checks the cleanliness and quality of the sample vial, and alerts you if the vial is missing or compromised.
Hach SC4500, SC1000 or legacy SC200 controller required
All turbidimeters must be used with a Hach digital controller (sold separately), such as the SC4500, SC1000 or legacy SC200. Calibration lid is also required; purchase separately (stock # 93661) or with maintenance kit (stock # 72855). If using Prognosys™ predictive diagnostics health monitoring system on an SC4500 or SC1000 controller, order a turbidimeter with internal system check capabilities.
All turbidimeters include: mounting bracket (fits pattern for legacy 1720E sensors), service vial removal tool, desiccant cartridge, flow regulator valve, integral 5-foot long digital cable and maintenance bracket (stores chamber lid and tools when performing routine maintenance).
MFR #DESCRIPTIONSTOCK #PRICE
TURBIDIMETERS
LXV445.99.10112TU5300sc Low-Range Turbidimeter93647$ 2,823.00
LXV445.99.13112TU5300sc Low-Range Turbidimeter w/ Internal System Check & RFID Capability936483,721.00
LXV445.99.11112TU5300sc Low-Range Turbidimeter w/ System Check2019383,271.00
LXV445.99.21112TU5300sc Low-Range Turbidimeter w/ Flow Sensor & System Check2019393,460.00
LXV445.99.23112TU5300sc Low-Range Turbidimeter w/ Flow Sensor, RFID & System Check2019403,907.00
LXV445.99.33112TU5300sc Low-Range Turbidimeter w/ Automatic Cleaning Module, System Check & RFID2019413,945.00
LXV445.99.53112TU5300sc Low-Range Turbidimeter w/ Automatic Cleaning Module, RFID, Flow Sensor & System Check2019423,985.00
LXV445.99.10212TU5400sc Ultra-High Precision Turbidimeter936497,873.00
LXV445.99.13212TU5400sc Ultra-High Precision Turbidimeter w/ Internal System Check & RFID Capability936508,746.00
RECOMMENDED CONTROLLERS (INCLUDE PROGNOSYS)
LXV525.99A11501SC4500 Digital Controller, 1 Input, 100-240 VAC99868$ 3,314.00
LXV525.99A11551SC4500 Digital Controller, 2 Input, 100-240 VAC998693,359.00
COMPLETE SYSTEMS (TURBIDIMETER & 2-INPUT SC4500 CONTROLLER)
LXV525.97KTO036TU5300sc Turbidimeter16507$ 5,726.00
LXV525.97KTO040TU5300sc Turbidimeter with System Check, RFID & Flow Sensor165096,759.00
LXV525.97KTO037TU5300sc Turbidimeter with System Check, RFID, Flow Sensor & Auto Cleaning Module165086,833.00
Range:0 to 700 NTU, FNU and FTU
Accuracy:±2% of reading plus 0.01 NTU (up to 40 NTU), ±10% of reading (over 40 NTU)*
Resolution:0.0001 NTU, FNU and FTU
Response time:T90 <30 seconds at 100 mL/min
Repeatability*
TU5300sc:<1% of reading or ±0.002 NTU, whichever is greater
TU5400sc:<1% of reading or ±0.0006 NTU, whichever is greater
Sample flow rate:100 to 1000 mL/min (1.6 to 15.9 gal/hour); optimal: 200 to 500 mL/min (3.2 to 7.9 gal/hour)
Outputs:varies based on connected controller
Power:supplied by controller via included cable
Cable:5'L integral digital type (extensions available)
Enclosure:indoor flat-surface mount (bracket included), 10.6"W x 7.5"H x 9.8"D
*Based on Formazin at 25°C (77°F).
Required & Recommended Accessories
Accessories are strongly recommended to ensure reliable results. In-line flow sensor (stock # 93652) lets you display inlet flow rate. Automatic cleaning module (stock # 93651) uses a motorized wiper that’s set to user-defined intervals (replaces the standard chamber lid).
Maintenance case/kit (stock # 72855) includes: calibration lid, Stablcal sealed vials with RFID (20 & 600 NTU), glass verification rod, microfiber cloth, manual vial wiper tool, vial compartment wipers, service tool, mobile service bracket, and hard carrying case.
MFR #DESCRIPTIONSTOCK #PRICE
RECOMMENDED ACCESSORIES
LQV160.99.00002Flow Sensor w/ 1/4" OD x 24"L Tubing93652$ 251.00
LQV159.97.00002Automatic Cleaning Module w/ Maintenance Bracket936511,167.00
CALIBRATION SOLUTIONS & ACCESSORIES
LZY904.97.00002Calibration Lid (Required; Included w/ Stock # 72855)93661$ 32.95
LZY898Stablcal Calibration Set (10, 20 & 600 NTU)93656668.00
LZY835Stablcal Calibration Set w/ RFID (10, 20 & 600 NTU)93657753.00
LZY901Glass Verification Rod, <0.1 NTU (Solid Secondary Standard)936601,568.00
MAINTENANCE KITS & ACCESSORIES
LZY907.97.00002Maintenance Case/Kit72855$ 1,809.00
LZY873Maintenance Bracket9365325.45
LZY903Manual Vial Wiper Tool9366424.79
LZY910Vial Compartment Wipers, Pack of 69366531.25
LZY945Microfiber Cloth9366624.79
REPLACEMENT ITEMS & ACCESSORIES
6122400Digital Extension Cable (Controller to Sensor), 3.3'L204614$ 332.00
5796000Digital Extension Cable (Controller to Sensor), 25'L204595310.00
Translucent LLDPE Tubing, 1/4" OD, 50' Roll7901717.49
LZY876Replacement Desiccant Drying Cartridge9366258.45
LZY834Replacement Process Sample Vial9366354.35
RFID TAGS
LZQ066Operator RFID Tags, Pack of 286133$ 31.20
LZQ067Sample RFID Tags/Stickers, Black, Pack of 39365458.85
LZQ070Sample RFID Tags/Stickers, Blue, Pack of 39365558.85

Hach TU5200 Benchtop Laser Turbidimeters
Part of the Hach Fall Promo!
Hach TU5200 Benchtop Laser Turbidimeters
• RFID-enabled turbidimeters allow quick, easy data transfer
• Store and organize up to 2000 data points with comments for easy recall
• Two USB ports let you connect flash drives, scanners, keyboards and more
Hach benchtop laser turbidimeters use 360° x 90° Detection, a patented optical design that captures 90º scatter through 360º of detection for maximum accuracy. This allows faster sample preparation than traditional methods, without the need for silicone oil and indexing.
Meters feature a large full-color touchscreen display, intuitive user interface and guided procedures. Multiple read modes let you see the exact data you need. Comparison mode displays both lab and process measurements (when used with the online TU5 turbidimeter as shown above), and alerts you if the difference between those readings falls outside your user-defined limit. Diagnostics show the status of the lid, sample vial, condensation and fouling. Security settings let you password protect your meter settings—let anyone on the team use it without risking accidental reconfiguration.
Store up to 2000 data points with comments, and organize them in reading, verification or calibration logs for easy retrieval. Quickly view a graph of the reading, or compare logs on the instrument display. Two USB ports let you connect to a barcode scanner, keyboard, printer, USB drive or server using a LAN connection.
RFID-enabled turbidimeters allow quick and easy data transfer
For added convenience, and prevention of manual errors, choose the RFID-enabled turbidimeter (stock # 93642). Add RFID tags to your samples to store data and transfer information between RFID-capable TU5 instruments.
When retrieving a process sample, hold the RFID tag near your TU5 online turbidimeter to collect the meter name, date, time and measured value. Once your sample is brought to the lab, simply hold the RFID tag near your benchtop turbidimeter to transfer the information. Then place the sample in the benchtop unit for measurement, and compare the measured values for instant validation. RFID operator ID tags also let personnel log into instruments with a swipe of their tag, and RFID labels on calibration standards let you pull up the Certificate of Analysis right on the meter.
Includes: Stablcal® calibration set (10-, 20- and 600-NTU standards in sealed vials), power supply, dust cover, vial stand and user manual. 1-year warranty. For turbidimeter with RFID capabilities (stock # 93642), you must purchase RFID tags separately.
MFR #DESCRIPTIONSTOCK #PRICE
TU5200 BENCHTOP LASER TURBIDIMETERS
LPV442.99.01012TU5200 Turbidimeter93641$ 5,766.00
LPV442.99.03012TU5200 Turbidimeter with RFID Capability936426,094.00
REPLACEMENT ITEMS & ACCESSORIES
LZV946Sample Vials, Pack of 293643$ 84.85
LZZ006Stablcal Calibration Set (1, 10 & 20 NTU)402950773.00
LZZ005Stablcal Calibration Set w/ RFID (1, 10 & 20 NTU)402949817.00
LZV898Stablcal Calibration Set (10, 20 & 600 NTU)93656668.00
LZY835Stablcal Calibration Set w/ RFID (10, 20 & 600 NTU)93657753.00
LZY899Stablcal 20-NTU Standard93658439.00
LZY837Stablcal 20-NTU Standard with RFID93659521.00
LZY900Stablcal 600-NTU Standard93644439.00
LZY838Stablcal 600-NTU Standard with RFID93645521.00
LZY901Glass Verification Rod, <0.1 NTU (Solid Secondary Standard)936601,568.00
LZQ066Operator RFID Tags, Pack of 28613331.20
LZQ067Sample RFID Tags/Stickers, Black, Pack of 39365458.85
LZQ070Sample RFID Tags/Stickers, Blue, Pack of 39365558.85
LQV157.99.50002Sipper Unit93646931.00
4397510Sample Degassing Kit32293135.00
LZY903Manual Vial Wiper Tool9366424.79
LZY945Microfiber Cloth9366624.79
KIMWIPES® Disposable Wipes, 4-1/2" x 8-1/2", Box of 280369896.35
Range:0 to 700 NTU, FNU, TE/F or FTU; 0 to 100 mg/L; 0 to 175 EBC
Resolution:0.0001 NTU
Accuracy:±2% of reading or ±0.01 NTU (the larger value) from 0 to 40 NTU; ±10% of reading from 40 to 700 NTU
Sample size:10 mL
USABlueBook: Hach's Premier Partner Since 1991
USABlueBook: Hach's Premier Partner Since 1991