Blue-White® F300 Flowmeter for 2-1/2" Pipe, Dual Scale 29-150 gpm (Sch 40), 25-130 gpm (Sch 80), F-30250-P
Description
- Accurate up to ±2% FS
- Convenient and economical flow measurement
F-300 flowmeters use a pitot tube pickup to measure clear water flow in closed full pipe systems. They mount easily via pipe saddle to existing Sch 40 or Sch 80 IPS horizonal pipe runs. Their one-piece, impact-resistant body features a PVDF float and permanent, easy-toread silkscreened scales (separate for Sch 40 and Sch 80).
Includes: stainless steel clamps, gasket and instructions.
Note: Meters require the drilling of a 5/8"-dia hole into the installation pipe.
Need repair parts for your pump? Use our quick-find selection tool now.
- Accuracy: To achieve ±2% full scale: min. of 10 pipe dia (upstream) & 4 pipe dia (downstream); To achieve ±5% full scale: min. of 5 pipe dia (upstream) & 2 pipe dia (downstream)
- Materials: cast acrylic body, 316 SS clamps, PVDF float, neoprene gasket
- Max working pressure: 75 psi @ 70°F
- Max fluid temperature: 190°F
- Height: 6"
Product Information
- Item number
- 67608
- Brand Name
- Blue-White
- Catalog Page
- 404
- Net weight
- 0.6
- Condition
- New
Blue-White® F300 Flowmeter for 2-1/2" Pipe, Dual Scale 29-150 gpm (Sch 40), 25-130 gpm (Sch 80), F-30250-P
- Item number
- 67608
- Brand Name
- Blue-White
- Catalog Page
- 404
- Net weight
- 0.6
- Condition
- New
- Accurate up to ±2% FS
- Convenient and economical flow measurement
F-300 flowmeters use a pitot tube pickup to measure clear water flow in closed full pipe systems. They mount easily via pipe saddle to existing Sch 40 or Sch 80 IPS horizonal pipe runs. Their one-piece, impact-resistant body features a PVDF float and permanent, easy-toread silkscreened scales (separate for Sch 40 and Sch 80).
Includes: stainless steel clamps, gasket and instructions.
Note: Meters require the drilling of a 5/8"-dia hole into the installation pipe.
Need repair parts for your pump? Use our quick-find selection tool now.
- Accuracy: To achieve ±2% full scale: min. of 10 pipe dia (upstream) & 4 pipe dia (downstream); To achieve ±5% full scale: min. of 5 pipe dia (upstream) & 2 pipe dia (downstream)
- Materials: cast acrylic body, 316 SS clamps, PVDF float, neoprene gasket
- Max working pressure: 75 psi @ 70°F
- Max fluid temperature: 190°F
- Height: 6"