Hach GLI Impeller Flow Sensor Pipe Mount, PVDF Body, Brass Sleeve, 20 ft Cable, F1A12D1T20P
Description
- Tee-mount, pipe thread and hot-tap versions
- Measure flow in pipe sizes from 1/2 to 100"
GLI insertion-type impeller flow sensors are excellent for measuring flow in wells, process control, effluent, irrigation and many other flow metering applications. Sensors are constructed of durable materials for long life and use a non-magnetic sensing system that does not create drag on the efficient 6-bladed impeller—providing good performance at low velocities. The GLI flow sensors can be mounted up to 2,000 feet away from the flow analyzer/display unit. Choose from the tee-mounted (socket) version for smaller pipe sizes or the adjustable pipe-thread mounted versions for use in pipes from 2 to 100".
Hot-tap sensors do not include ball valve. Tee-mount sensors require GLI mounting hardware listed below
Note: this item may be restricted from sale in certain states. Please check with your local governing body to ensure compliance with all laws and regulations.
Per the Federal Reduction of Lead in Drinking Water Act – this item cannot be used in potable (drinking) water applications
- Measuring range: 1 to 30 ft/sec
- Accuracy: ±1% of full scale from 1 to 30 ft/sec
- Repeatability: plus or minus 0.5% of full scale
- Linearity: plus or minus 1% of full scale
- Max pressure: 400 psi @ 221°F
Product Information
- Item number
- 40283
- Brand Name
- Hach Company
- Catalog Page
- 412
- Net weight
- 4.6
- Condition
- New
Alternate
Hach GLI Impeller Flow Sensor Pipe Mount, PVDF Body, Brass Sleeve, 20 ft Cable, F1A12D1T20P
- Item number
- 40283
- Brand Name
- Hach Company
- Catalog Page
- 412
- Net weight
- 4.6
- Condition
- New
- Tee-mount, pipe thread and hot-tap versions
- Measure flow in pipe sizes from 1/2 to 100"
GLI insertion-type impeller flow sensors are excellent for measuring flow in wells, process control, effluent, irrigation and many other flow metering applications. Sensors are constructed of durable materials for long life and use a non-magnetic sensing system that does not create drag on the efficient 6-bladed impeller—providing good performance at low velocities. The GLI flow sensors can be mounted up to 2,000 feet away from the flow analyzer/display unit. Choose from the tee-mounted (socket) version for smaller pipe sizes or the adjustable pipe-thread mounted versions for use in pipes from 2 to 100".
Hot-tap sensors do not include ball valve. Tee-mount sensors require GLI mounting hardware listed below
Note: this item may be restricted from sale in certain states. Please check with your local governing body to ensure compliance with all laws and regulations.
Per the Federal Reduction of Lead in Drinking Water Act – this item cannot be used in potable (drinking) water applications
- Measuring range: 1 to 30 ft/sec
- Accuracy: ±1% of full scale from 1 to 30 ft/sec
- Repeatability: plus or minus 0.5% of full scale
- Linearity: plus or minus 1% of full scale
- Max pressure: 400 psi @ 221°F