Myron L TP1 Conductivity Meter, 0-1000 uS, 10-20 mS
Description
- Cup-style design measures all three parameters with one sample
This simple-to-use meter measures the water quality of influent, wastewater, boiler water and cooling tower water. Take readings easily by rinsing and filling sensor cup with a 5-mL sample. Then push a parameter button to display temperature as well as conductivity or TDS. Readings are automatically temperature compensated with the built-in sensor.
IP67-rated waterproof ABS housing features a four-digit LCD. The auto shut-off prolongs battery life to over 100 hours from one 9V battery.
Includes: one 9V battery and instruction manual. 2-year meter warranty.
- Conductivity range: 0 to 9.99, 10 to 99.99, 100 to 999.9, 1000 to 9999 µS; 10 to 20 mS
- Conductivity resolution: 0.01, 0.1, 1.0 µS; 0.01 mS
- Conductivity accuracy: ±1% of reading
- TDS range: 0 to 9.99, 10 to 99.99, 100 to 999.9, 1000 to 9999 ppm; 10 to 20 ppt
- TDS resolution: 0.01, 0.1, 1.0 ppm; 0.01 ppt
- TDS accuracy: ±1% of reading
- Temperature range: 32 to 160°F (0 to 71°C)
- Temperature resolution: 0.1°F/°C
- Temperature accuracy: ±0.1°C
Product Information
- Item number
- 40317
- Brand Name
- Myron L Co.
- Catalog Page
- 681
- Net weight
- 1.2
- Condition
- New
Myron L TP1 Conductivity Meter, 0-1000 uS, 10-20 mS
- Item number
- 40317
- Brand Name
- Myron L Co.
- Catalog Page
- 681
- Net weight
- 1.2
- Condition
- New
- Cup-style design measures all three parameters with one sample
This simple-to-use meter measures the water quality of influent, wastewater, boiler water and cooling tower water. Take readings easily by rinsing and filling sensor cup with a 5-mL sample. Then push a parameter button to display temperature as well as conductivity or TDS. Readings are automatically temperature compensated with the built-in sensor.
IP67-rated waterproof ABS housing features a four-digit LCD. The auto shut-off prolongs battery life to over 100 hours from one 9V battery.
Includes: one 9V battery and instruction manual. 2-year meter warranty.
- Conductivity range: 0 to 9.99, 10 to 99.99, 100 to 999.9, 1000 to 9999 µS; 10 to 20 mS
- Conductivity resolution: 0.01, 0.1, 1.0 µS; 0.01 mS
- Conductivity accuracy: ±1% of reading
- TDS range: 0 to 9.99, 10 to 99.99, 100 to 999.9, 1000 to 9999 ppm; 10 to 20 ppt
- TDS resolution: 0.01, 0.1, 1.0 ppm; 0.01 ppt
- TDS accuracy: ±1% of reading
- Temperature range: 32 to 160°F (0 to 71°C)
- Temperature resolution: 0.1°F/°C
- Temperature accuracy: ±0.1°C