Product Details GLI DRY-CAL™ calibration system for unsurpassed accuracy and reliability Three measurement modes, four temperature compensation methods Single input reads and transmits the output signal This field-proven design incorporates the GLI DRY-CAL calibration system, which does not re
Price $964
price per each
excl. tax
Call for availability

Description

Product Details
  • GLI DRY-CAL™ calibration system for unsurpassed accuracy and reliability
  • Three measurement modes, four temperature compensation methods
  • Single input reads and transmits the output signal

This field-proven design incorporates the GLI DRY-CAL calibration system, which does not require a conductivity calibration solution. You can also use a single point sample of known conductivity to calibrate the transmitter and sensor. Zero the PRO-C3 by simply holding the dry sensor in the air for zero calibration.

Measure conductivity in µS or mS, total dissolved solids in ppm or ppb, and resistivity in MW or KW. Depending upon the measurement parameter you select, the transmitter can provide the following methods for temperature compensation: linear slope (% per °C), built-in natural water properties table, ammonia properties table or no temperature compensation.

Use the passcode feature to restrict access to only authorized personnel. A 24 VDC power supply (stock #71003) is required for operation. Graphite or stainless steel sensors are available for use with the transmitter. The usable measurement range for a cell constant k = 0.5 is 0 µS/cm to 1,000 µS/cm. Locate the conductivity sensor up to 300 feet away from the analyzer.

Note: Must use contacting sensors (stock #28203, 28204 or 28199)

Product Information

Item number
28202
Brand Name
Hach Company
Net weight
1.4
Condition
New

Documents

Hach GLI PRO-C3 Contacting Conductivity/Resistivity/TDS Transmitter, 4 - 20 mA output, PRO-C3A1N

Item number
28202
Brand Name
Hach Company
Net weight
1.4
Condition
New
Price $964
price per each
excl. tax
Call for availability
each
Need Help? Call 800-548-1234
Product Details
  • GLI DRY-CAL™ calibration system for unsurpassed accuracy and reliability
  • Three measurement modes, four temperature compensation methods
  • Single input reads and transmits the output signal

This field-proven design incorporates the GLI DRY-CAL calibration system, which does not require a conductivity calibration solution. You can also use a single point sample of known conductivity to calibrate the transmitter and sensor. Zero the PRO-C3 by simply holding the dry sensor in the air for zero calibration.

Measure conductivity in µS or mS, total dissolved solids in ppm or ppb, and resistivity in MW or KW. Depending upon the measurement parameter you select, the transmitter can provide the following methods for temperature compensation: linear slope (% per °C), built-in natural water properties table, ammonia properties table or no temperature compensation.

Use the passcode feature to restrict access to only authorized personnel. A 24 VDC power supply (stock #71003) is required for operation. Graphite or stainless steel sensors are available for use with the transmitter. The usable measurement range for a cell constant k = 0.5 is 0 µS/cm to 1,000 µS/cm. Locate the conductivity sensor up to 300 feet away from the analyzer.

Note: Must use contacting sensors (stock #28203, 28204 or 28199)