Hach GLI PRO-C3 Contacting Conductivity/Resistivity/TDS Transmitter, 4 - 20 mA output, PRO-C3A1N
Description
- GLI DRY-CAL™ calibration system for unsurpassed accuracy and reliability
- Three measurement modes, four temperature compensation methods
- Single input reads and transmits the output signal
This field-proven design incorporates the GLI DRY-CAL calibration system, which does not require a conductivity calibration solution. You can also use a single point sample of known conductivity to calibrate the transmitter and sensor. Zero the PRO-C3 by simply holding the dry sensor in the air for zero calibration.
Measure conductivity in µS or mS, total dissolved solids in ppm or ppb, and resistivity in MW or KW. Depending upon the measurement parameter you select, the transmitter can provide the following methods for temperature compensation: linear slope (% per °C), built-in natural water properties table, ammonia properties table or no temperature compensation.
Use the passcode feature to restrict access to only authorized personnel. A 24 VDC power supply (stock #71003) is required for operation. Graphite or stainless steel sensors are available for use with the transmitter. The usable measurement range for a cell constant k = 0.5 is 0 µS/cm to 1,000 µS/cm. Locate the conductivity sensor up to 300 feet away from the analyzer.
Note: Must use contacting sensors (stock #28203, 28204 or 28199)
Product Information
- Item number
- 28202
- Brand Name
- Hach Company
- Net weight
- 1.4
- Condition
- New
Hach GLI PRO-C3 Contacting Conductivity/Resistivity/TDS Transmitter, 4 - 20 mA output, PRO-C3A1N
- Item number
- 28202
- Brand Name
- Hach Company
- Net weight
- 1.4
- Condition
- New
- GLI DRY-CAL™ calibration system for unsurpassed accuracy and reliability
- Three measurement modes, four temperature compensation methods
- Single input reads and transmits the output signal
This field-proven design incorporates the GLI DRY-CAL calibration system, which does not require a conductivity calibration solution. You can also use a single point sample of known conductivity to calibrate the transmitter and sensor. Zero the PRO-C3 by simply holding the dry sensor in the air for zero calibration.
Measure conductivity in µS or mS, total dissolved solids in ppm or ppb, and resistivity in MW or KW. Depending upon the measurement parameter you select, the transmitter can provide the following methods for temperature compensation: linear slope (% per °C), built-in natural water properties table, ammonia properties table or no temperature compensation.
Use the passcode feature to restrict access to only authorized personnel. A 24 VDC power supply (stock #71003) is required for operation. Graphite or stainless steel sensors are available for use with the transmitter. The usable measurement range for a cell constant k = 0.5 is 0 µS/cm to 1,000 µS/cm. Locate the conductivity sensor up to 300 feet away from the analyzer.
Note: Must use contacting sensors (stock #28203, 28204 or 28199)