Rosemount 2051 Pressure Transmitter Differential, -25 to 25" H2O, 2051CD1A22A1A
Description
- High ±0.10% accuracy
- Features polyurethane-covered aluminum enclosure, NEMA 4X
This differential pressure transmitter features a two-wire 4-20 mA output that is user-selectable for linear or square root output. A standard HART signal is superimposed concurrently on the 4-20 mA output. External power supply is required.
Differential transmitters include: traditional flange with 1/4" NPT connection. To convert to 1/2" NPT connection, order the optional flange adapters (stock # 44981). Options such as 3-valve manifolds (stock # 44978) and others are available. Contact USABlueBook for information on special-order transmitters with higher accuracy, NSF drinking water approvals, hazardous location certifications, and more.
Note: Transmitters are factory calibrated, pressure tested and ready to install. Please provide us with the appropriate set points for both 4 mA and 20 mA for your blind unit (without a LOI). USABlueBook stocks these blind units and can program to your range specifications and ship them in 1-2 days!
- Turndown ratio: 100:7
- Overpressure: up to 2000 psi
- Sensing element: 316L SS diaphragm
- Process connection: 1/4" NPT(F)
- Power: 10.5 to 42.4 VDC (no load)
Product Information
- Item number
- 44969
- Brand Name
- Emerson/Rosemount
- Catalog Page
- 866
- Net weight
- 10
- Condition
- New
Accessories
Alternate
Related
Rosemount 2051 Pressure Transmitter Differential, -25 to 25" H2O, 2051CD1A22A1A
- Item number
- 44969
- Brand Name
- Emerson/Rosemount
- Catalog Page
- 866
- Net weight
- 10
- Condition
- New
- High ±0.10% accuracy
- Features polyurethane-covered aluminum enclosure, NEMA 4X
This differential pressure transmitter features a two-wire 4-20 mA output that is user-selectable for linear or square root output. A standard HART signal is superimposed concurrently on the 4-20 mA output. External power supply is required.
Differential transmitters include: traditional flange with 1/4" NPT connection. To convert to 1/2" NPT connection, order the optional flange adapters (stock # 44981). Options such as 3-valve manifolds (stock # 44978) and others are available. Contact USABlueBook for information on special-order transmitters with higher accuracy, NSF drinking water approvals, hazardous location certifications, and more.
Note: Transmitters are factory calibrated, pressure tested and ready to install. Please provide us with the appropriate set points for both 4 mA and 20 mA for your blind unit (without a LOI). USABlueBook stocks these blind units and can program to your range specifications and ship them in 1-2 days!
- Turndown ratio: 100:7
- Overpressure: up to 2000 psi
- Sensing element: 316L SS diaphragm
- Process connection: 1/4" NPT(F)
- Power: 10.5 to 42.4 VDC (no load)