HOBO® UX120-Series 4-Channel Analog Data Logger, UX120-006M

Item No.19451
Product Details HOBO's highest accuracy data logger! Flexible analog input for a wide range of applications Battery powered for use virtually anywhere The HOBO UX120 analog logger is a high-performance LCD-display instrument with the highest accuracy of any HOBO logger. It supports up to four extern
Price $217.95
price per each
excl. tax
In Stock

Description

Product Details
  • HOBO's highest accuracy data logger!
  • Flexible analog input for a wide range of applications
  • Battery powered for use virtually anywhere

The HOBO UX120 analog logger is a high-performance LCD-display instrument with the highest accuracy of any HOBO logger. It supports up to four external 4-20 mA sensors and stores up to 1.9 million measurements. Universal input lets you use the logger in many applications—track pressure transmitter values, process analyzer equipment signals, or any 4-20 mA sensor. One unit can replace up to four circular chart recorders.

The display confirms logger operation and shows near real-time measurement data and local process indication for up to four channels at a time. It also displays on-screen alarms for user-defined thresholds. The logger can provide minimum, maximum, average and standard deviation data. For a complete analog system, order a 4-20 mA cable for each input (stock # 19452). Both AC and DC voltages can also be logged with appropriate sensors and cabling; contact USABlueBook for details.

Logger requires either HOBOware or HOBOware Pro software. HOBOware software provides basic logger setup, graphing and data analysis. It is available for free download from onsetcomp.com. HOBOware Pro Software (stock # 10045) features advanced functionality.

Includes: batteries and mounting hardware.

Note: NIST-traceable analog loggers are available. Contact USABlueBook for details.

Tech Specs:
  • Range: 0 to 20.1 mA; 0 to 2.5/5.0 V/10 V/24 V
  • Accuracy: ±0.001 mA, ±0.2% of reading; ±0.1 mV ±0.1% of reading (best case, voltage input)
  • Resolution: 0.3 µA (4-20 mA); 40 µV (best case, voltage input)
  • Sample interval: 1 second to 18 hours, 12 minutes, 15 seconds
  • Data storage: 1.9 million measurements

Product Information

Item number
19451
Brand Name
Onset Computer
Net weight
0.1
Condition
New

HOBO® UX120-Series 4-Channel Analog Data Logger, UX120-006M

Item number
19451
Brand Name
Onset Computer
Net weight
0.1
Condition
New
Price $217.95
price per each
excl. tax
In Stock
each
Need Help? Call 800-548-1234
Product Details
  • HOBO's highest accuracy data logger!
  • Flexible analog input for a wide range of applications
  • Battery powered for use virtually anywhere

The HOBO UX120 analog logger is a high-performance LCD-display instrument with the highest accuracy of any HOBO logger. It supports up to four external 4-20 mA sensors and stores up to 1.9 million measurements. Universal input lets you use the logger in many applications—track pressure transmitter values, process analyzer equipment signals, or any 4-20 mA sensor. One unit can replace up to four circular chart recorders.

The display confirms logger operation and shows near real-time measurement data and local process indication for up to four channels at a time. It also displays on-screen alarms for user-defined thresholds. The logger can provide minimum, maximum, average and standard deviation data. For a complete analog system, order a 4-20 mA cable for each input (stock # 19452). Both AC and DC voltages can also be logged with appropriate sensors and cabling; contact USABlueBook for details.

Logger requires either HOBOware or HOBOware Pro software. HOBOware software provides basic logger setup, graphing and data analysis. It is available for free download from onsetcomp.com. HOBOware Pro Software (stock # 10045) features advanced functionality.

Includes: batteries and mounting hardware.

Note: NIST-traceable analog loggers are available. Contact USABlueBook for details.

Tech Specs:
  • Range: 0 to 20.1 mA; 0 to 2.5/5.0 V/10 V/24 V
  • Accuracy: ±0.001 mA, ±0.2% of reading; ±0.1 mV ±0.1% of reading (best case, voltage input)
  • Resolution: 0.3 µA (4-20 mA); 40 µV (best case, voltage input)
  • Sample interval: 1 second to 18 hours, 12 minutes, 15 seconds
  • Data storage: 1.9 million measurements