Hach FL900 Basic Flow Logger, 1 Input, FL900.97

Item No.13181
Product Details Log I & I and CSO data long-term on just battery power Universal input accepts multiple types of Hach open-channel flow sensors Rugged construction withstands installation in manholes and sewers Reduce monitoring costs, increase efficiency and collect reliable data 24/7 with these in
Price $5414.4
price per each
excl. tax
Call for availability

Description

Product Details
  • Log I & I and CSO data long-term on just battery power
  • Universal input accepts multiple types of Hach open-channel flow sensors
  • Rugged construction withstands installation in manholes and sewers

Reduce monitoring costs, increase efficiency and collect reliable data 24/7 with these innovative flow loggers. Use them for short- or long-term open-channel flow monitoring studies, such as inflow and infiltration (I & I), combined sewer overflow (CSO), capacity planning and stormwater runoff monitoring. Their long battery life (up to 306 days) and rugged IP68 housing mean you can install them wherever you want—including manholes and sewers.

To set up your logger, simply download the free FSDATA® Desktop Instrument Manager software from hach.com/flow. Then, connect your logger to a laptop or PC to run through a series of intuitive setup options. You can readily define logging intervals that balance greater data resolution during high-flow periods with battery/data volume conservation during low-flow seasons. Physical installation involves simple wall-mount or ladder-rung suspension (mounting hardware and accessories sold separately).

Logger features a plug-and-play port that accepts direct connection of one sensor, including the FLO-DAR® AV, and Down-Looking and In-Pipe ultrasonic sensors. You can also connect a Hach SubAV sensor by equipping your logger with an AV9000 analyzer module (stock # 13189).

In addition to the sensor port, logger features an auxiliary port for connection to a power source or for communication with Hach AS950 or third-party autosamplers (requires cable, sold separately). Enclosure is rated NEMA 6P/IP68.

Unit logs and stores up to 325,000 data points for your selected flow events and/or sample events. Retrieve data via a USB cable. Up to 16 different alarms are available for flow (high/high, high, low, low/low), system (low battery, low memory, full memory, sensor timeout/error) and actions (trigger sampler, change logging interval). Other models and configurations are available; contact us for details.

Includes: four 6V alkaline lantern batteries, stainless steel suspension mounting cable and instruction manual.

For a complete system, order:
1. FL900 series flow logger
2. FSDATA Desktop Instrument Manager software (free download at hach.com/flow)
3. Communication cable (stock # 204640)
4. Sensors (sold separately; loggers accept up to four sensors depending on model)
• FLO-DAR (Flow)
• SubAV Sensor with AV9000S Module (Flow)
• Ultrasonic: Down-Looking or In-Pipe (Flow)
5. Other options:
• Rain Gauge; stock #14103, for models with rain gauge port
• AS950 Advanced Sampler
6. Mounting brackets/hardware
7. Accessories as required for your application

Tech Specs:
  • Inputs: 1
  • Communication: USB and RS232 MODBUS RTU (not simultaneous)
  • Supply voltage: 8 to 18 VDC (batteries included) or external source
  • Data logger: 325,000 flow sensor measurements, 1000 events, 2000 sample events (1 to 60 min intervals, primary and secondary)
  • Dimensions: 8.7"W x 16"H x 10"D

Product Information

Item number
13181
Brand Name
Hach Company
Catalog Page
433
Net weight
22.2
Condition
New

Hach FL900 Basic Flow Logger, 1 Input, FL900.97

Item number
13181
Brand Name
Hach Company
Catalog Page
433
Net weight
22.2
Condition
New
Price $5414.4
price per each
excl. tax
Call for availability
each
Need Help? Call 800-548-1234
Product Details
  • Log I & I and CSO data long-term on just battery power
  • Universal input accepts multiple types of Hach open-channel flow sensors
  • Rugged construction withstands installation in manholes and sewers

Reduce monitoring costs, increase efficiency and collect reliable data 24/7 with these innovative flow loggers. Use them for short- or long-term open-channel flow monitoring studies, such as inflow and infiltration (I & I), combined sewer overflow (CSO), capacity planning and stormwater runoff monitoring. Their long battery life (up to 306 days) and rugged IP68 housing mean you can install them wherever you want—including manholes and sewers.

To set up your logger, simply download the free FSDATA® Desktop Instrument Manager software from hach.com/flow. Then, connect your logger to a laptop or PC to run through a series of intuitive setup options. You can readily define logging intervals that balance greater data resolution during high-flow periods with battery/data volume conservation during low-flow seasons. Physical installation involves simple wall-mount or ladder-rung suspension (mounting hardware and accessories sold separately).

Logger features a plug-and-play port that accepts direct connection of one sensor, including the FLO-DAR® AV, and Down-Looking and In-Pipe ultrasonic sensors. You can also connect a Hach SubAV sensor by equipping your logger with an AV9000 analyzer module (stock # 13189).

In addition to the sensor port, logger features an auxiliary port for connection to a power source or for communication with Hach AS950 or third-party autosamplers (requires cable, sold separately). Enclosure is rated NEMA 6P/IP68.

Unit logs and stores up to 325,000 data points for your selected flow events and/or sample events. Retrieve data via a USB cable. Up to 16 different alarms are available for flow (high/high, high, low, low/low), system (low battery, low memory, full memory, sensor timeout/error) and actions (trigger sampler, change logging interval). Other models and configurations are available; contact us for details.

Includes: four 6V alkaline lantern batteries, stainless steel suspension mounting cable and instruction manual.

For a complete system, order:
1. FL900 series flow logger
2. FSDATA Desktop Instrument Manager software (free download at hach.com/flow)
3. Communication cable (stock # 204640)
4. Sensors (sold separately; loggers accept up to four sensors depending on model)
• FLO-DAR (Flow)
• SubAV Sensor with AV9000S Module (Flow)
• Ultrasonic: Down-Looking or In-Pipe (Flow)
5. Other options:
• Rain Gauge; stock #14103, for models with rain gauge port
• AS950 Advanced Sampler
6. Mounting brackets/hardware
7. Accessories as required for your application

Tech Specs:
  • Inputs: 1
  • Communication: USB and RS232 MODBUS RTU (not simultaneous)
  • Supply voltage: 8 to 18 VDC (batteries included) or external source
  • Data logger: 325,000 flow sensor measurements, 1000 events, 2000 sample events (1 to 60 min intervals, primary and secondary)
  • Dimensions: 8.7"W x 16"H x 10"D