Keller LevelRat Submersible Level Transmitter, 0 to 10 psi (0 to 23.10 ft/H2O), 40'L Cable

Item No.70801
Product Details Large 1.2" non-fouling sensing diaphragm Great for lift stations, heavy solids-laden liquids and slurries Dual outputs: 4-20mA and RS485 LevelRat submersible transmitters withstand harsh conditions found in sewage lift station and raw wastewater sites. Rugged stainless steel construc
Price $661
price per each
excl. tax
In Stock

Description

Product Details
  • Large 1.2" non-fouling sensing diaphragm
  • Great for lift stations, heavy solids-laden liquids and slurries
  • Dual outputs: 4-20mA and RS485

LevelRat submersible transmitters withstand harsh conditions found in sewage lift station and raw wastewater sites. Rugged stainless steel construction with a unique nonstick diaphragm offers superior durability and abrasion resistance. These 1-1/4" diameter models install via cable suspension.

All Keller transmitters feature an integral cable vent tube for fast response and accurate readings, a lifetime lightning/surge protection guarantee and are made in the USA.

Transmitters offer dual outputs for flexibility:
One RS-485 and one rescalable analog 4-20 mA. The RS-485 connection lets you retrieve both level and temperature data, and rescale the analog output from 10% to 110% of the basic range. To rescale the output, you must briefly interface the transmitter with a PC running Keller's free downloadable Control Center 30 (CCS30) software, and also purchase a converter cable (stock # 71767).

Optional accessories:
Line Protector (stock # 71154) provides additional lightning/surge protection on external wiring. To protect vent tube ends in humid environments, install a drying tube assembly (stock # 71087).

Don't see what you need here? Custom models are available for all transmitters, with typical shipping times of under one week. Options include pressure ranges, cable lengths, wetted materials, and models tolerating supply voltages below 11 VDC. Contact Technical Support for more information.

NOTE: Supply voltages ≥15 VDC recommended; adequate supply voltage depends upon application specifics. Long cable lengths and ancillary equipment in the loop can increase supply voltage requirements. Contact Technical Support to discuss your application.

Tech Specs:
  • Range (PSI): 0 to 10
  • Range (ft/H2O): 0 to 23.10
  • Cable length: 40'
  • Wetted materials: 316 L stainless steel, Kynar®
  • Cable: polyethylene (PE) jacket and EPDM seal
  • Accuracy: ±0.5% full scale (static)
  • Power: 11-28 VDC (min. 15 VDC recommended)
  • Output: 4-20 mA, 2-wire and RS-485 Modbus
  • Temperature range: 14 to 140°F (compensated)
  • Dimensions: 1.26"Dia x 4.37"L

Product Information

Item number
70801
Brand Name
Keller
Catalog Page
846
Net weight
1.4
Condition
New

Keller LevelRat Submersible Level Transmitter, 0 to 10 psi (0 to 23.10 ft/H2O), 40'L Cable

Item number
70801
Brand Name
Keller
Catalog Page
846
Net weight
1.4
Condition
New
Price $661
price per each
excl. tax
In Stock
each
Need Help? Call 800-548-1234
Product Details
  • Large 1.2" non-fouling sensing diaphragm
  • Great for lift stations, heavy solids-laden liquids and slurries
  • Dual outputs: 4-20mA and RS485

LevelRat submersible transmitters withstand harsh conditions found in sewage lift station and raw wastewater sites. Rugged stainless steel construction with a unique nonstick diaphragm offers superior durability and abrasion resistance. These 1-1/4" diameter models install via cable suspension.

All Keller transmitters feature an integral cable vent tube for fast response and accurate readings, a lifetime lightning/surge protection guarantee and are made in the USA.

Transmitters offer dual outputs for flexibility:
One RS-485 and one rescalable analog 4-20 mA. The RS-485 connection lets you retrieve both level and temperature data, and rescale the analog output from 10% to 110% of the basic range. To rescale the output, you must briefly interface the transmitter with a PC running Keller's free downloadable Control Center 30 (CCS30) software, and also purchase a converter cable (stock # 71767).

Optional accessories:
Line Protector (stock # 71154) provides additional lightning/surge protection on external wiring. To protect vent tube ends in humid environments, install a drying tube assembly (stock # 71087).

Don't see what you need here? Custom models are available for all transmitters, with typical shipping times of under one week. Options include pressure ranges, cable lengths, wetted materials, and models tolerating supply voltages below 11 VDC. Contact Technical Support for more information.

NOTE: Supply voltages ≥15 VDC recommended; adequate supply voltage depends upon application specifics. Long cable lengths and ancillary equipment in the loop can increase supply voltage requirements. Contact Technical Support to discuss your application.

Tech Specs:
  • Range (PSI): 0 to 10
  • Range (ft/H2O): 0 to 23.10
  • Cable length: 40'
  • Wetted materials: 316 L stainless steel, Kynar®
  • Cable: polyethylene (PE) jacket and EPDM seal
  • Accuracy: ±0.5% full scale (static)
  • Power: 11-28 VDC (min. 15 VDC recommended)
  • Output: 4-20 mA, 2-wire and RS-485 Modbus
  • Temperature range: 14 to 140°F (compensated)
  • Dimensions: 1.26"Dia x 4.37"L