Match your online turbidity measurements with those in the lab!
Be confident your turbidity readings are accurate with TU5 Series laboratory and process turbidimeters. Both lab and process models use identical 360° x 90° Detection™ technology optical components—delivering precise readings that virtually eliminate variability between the instruments.
Hach TU5300sc & TU5400sc Online Laser Turbidimeters93650
RFID-enabled turbidimeters allow quick, easy data transfer
Hach TU5300sc & TU5400sc Online Laser Turbidimeters
Patented optical 360° x 90° Detection for maximum accuracy and repeatability
Small sample volume delivers immediate readings and allows faster cleaning
These turbidimeters deliver outstanding low-level precision and sensitivity. Patented optical 360° x 90° Detection captures 90° scatter through 360° of detection for maximum accuracy. Meters deliver immediate readings, thanks to their small sample surface chamber volume—up to 98% smaller than other meters. This also makes cleaning much easier.
Sensors track internal temperature and humidity, alerting you to condensation issues. They use quick-replacement sealed vials for easy calibration. An active drying system with desiccant cartridge and air pump circulates dried air throughout the sample cell compartment.
Choose from TU5300sc low-range models or TU5400sc ultra-high precision models with increased repeatability. Both offer exceptional performance in drinking water and other high-purity water applications. All turbidimeters must be used in conjunction with a Hach digital sc200 or sc1000 controller (sold separately).
For added convenience and prevention of manual errors, choose RFID-enabled turbidimeters. Simply add RFID tags to your samples to store data and transfer information between RFID-capable TU5 instruments, including benchtop turbidimeters. These units also feature Internal System Check, which automatically checks the cleanliness and quality of the sample vial, and alerts you if the vial is missing or compromised.
All turbidimeters include: mounting bracket (fits pattern for 1720E sensors), service vial removal tool, desiccant cartridge, flow regulator valve, integral 5'L digital cable, and 500-mL bottle of 20-NTU StablCal® with syringe. TU5400sc turbidimeters also include: maintenance bracket, which stores your chamber lid and tools when you are performing routine maintenance. Bracket also sold separately (stock # 93653) for TU5300sc turbidimeters.
Note: A Hach sc200 or sc1000 digital controller (sold separately) is required to operate the turbidimeters. Calibration lid is also required; purchase separately (stock # 93661) or with maintenance kit (stock # 72855). If using Prognosys™ diagnostics system on an sc1000 controller, you must order turbidimeter with internal system check capabilities.
Range: 0 to 700 NTU, FNU & FTU
Accuracy: ±2% of reading plus 0.01 NTU (up to 40 NTU),
±10% of reading (over 40 NTU)*
Resolution: 0.0001 NTU, FNU & FTU
Response time: T90 <30 seconds at 100 mL/min
Repeatability*
TU5300sc: <1% of reading or ±0.002 NTU, whichever is greater
TU5400sc: <1% of reading or ±0.0006 NTU, whichever is greater
Sample flow rate: 100 to 1000 mL/min (1.6 to 15.9 gal/hour);
optimal: 200 to 500 mL/min (3.2 to 7.9 gal/hour)
Outputs: varies based on connected controller
Power: supplied by controller via included cable
Cable: 5'L integral digital type (extensions available)
Enclosure: indoor flat-surface mount (bracket included),
10.6"W x 7.5"H x 9.8"D
*Based on Formazin at 25°C (77°F).
MFR # DESCRIPTION STOCK #
TURBIDIMETERS
LXV445.99.10112 TU5300sc Low-Range Turbidimeter 93647
LXV445.99.13112 TU5300sc Low-Range Turbidimeter w/ Internal System Check & RFID Capability 93648
LXV445.99.10212 TU5400sc Ultra-High Precision Turbidimeter 93649
LXV445.99.13212 TU5400sc Ultra-High Precision Turbidimeter w/ Internal System Check & RFID Capability 93650
CONTROLLERS
LXV404.99.00502 sc200 Digital Controller, 1 Input, 100-240 VAC 29175
LXV404.99.00552 sc200 Digital Controller, 2 Input, 100-240 VAC 202010
Accessories
Optional accessories are strongly recommended to ensure reliable results. In-line flow sensor (stock # 93652) lets you display inlet flow rate. Automatic cleaning module (stock # 93651) uses a motorized wiper that’s set to user-defined intervals (replaces the standard chamber lid).
Maintenance case/kit (stock # 72855) includes: calibration lid, StablCal sealed vials with RFID (20 and 600 NTU), glass verification rod, microfiber cloth, manual vial wiper tool, vial compartment wipers, service tool, mobile service bracket and hard carrying case.
MFR # DESCRIPTION STOCK #
RFID TAGS
LZQ066 Operator RFID Tags, Pack of 2 86133
LZQ067 Sample RFID Tags/Stickers, Black, Pack of 3 93654
LZQ070 Sample RFID Tags/Stickers, Blue, Pack of 3 93655
RECOMMENDED ACCESSORIES
LQV160.99.00002 In-Line Flow Sensor w/ 1/4"OD x 24"L Tubing 93652
LQV159.97.00002 Automatic Cleaning Module w/ Maint. Bracket 93651
CALIBRATION SOLUTIONS & ACCESSORIES
LZY904.97.00002 Calibration Lid (Required) 93661
LZY898 StablCal Calibration Set (10, 20 & 600 NTU) 93656
LZY835 StablCal Calibration Set w/ RFID (10, 20 & 600 NTU) 93657
LZY901 Glass Verification Rod, <0.1 NTU (Solid Secondary Standard) 93660
MAINTENANCE KITS & ACCESSORIES
LZY907.97.00002 Maintenance Case/Kit 72855
LZY873 Maintenance Bracket (Included w/ TU5400sc) 93653
LZY903 Manual Vial Wiper Tool 93664
LZY910 Vial Compartment Wipers, Pack of 6 93665
LZY945 Microfiber Cloth and Pack of Wi 93666
REPLACEMENT ITEMS & ACCESSORIES
6122400 Digital Extension Cable (Controller to Sensor), 3.3'L 204614
5796000 Digital Extension Cable (Controller to Sensor), 25'L 204595
Translucent LLDPE Tubing, 1/4&qtuo;OD, 50' Roll 79017
LZY876 Replacement Desiccant Drying Cartridge 93662
LZY834 Replacement Process Sample Vial 93663
Hach CL17sc Chlorine Analyzers
Hach TU5200 Benchtop Laser Turbidimeters
Store and organize up to 2000 data points with comments for easy recall
Two USB ports let you connect flash drives, scanners, keyboards and more
RFID-enabled turbidimeters allow quick and easy data transfer
Hach benchtop laser turbidimeters use 360° x 90° Detection, a patented optical design that captures 90° scatter through 360° of detection for maximum accuracy. This allows faster sample preparation than traditional methods, without the need for silicone oil and indexing.
Meters feature a large full-color touchscreen display, intuitive user interface and guided procedures. Multiple read modes let you see the exact data you need. Comparison mode displays both lab and process measurements (when used with the online TU5 turbidimeter as shown on facing page), and alerts you if the difference between those readings falls outside your user-defined limit. Diagnostics show the status of the lid, sample vial, condensation and fouling. Security settings let you password protect your meter settings—let anyone on the team use it without risking accidental reconfiguration.
Store up to 2000 data points with comments, and organize them in reading, verification or calibration logs for easy retrieval. Quickly view a graph of the reading, or compare logs on the instrument display. Two USB ports let you connect to a barcode scanner, keyboard, printer, USB drive or server using a LAN connection.
RFID-enabled turbidimeters allow quick and easy data transfer
For added convenience, and prevention of manual errors, choose the RFID-enabled turbidimeter (stock # 93642). Add RFID tags to your samples to store data and transfer information between RFID-capable TU5 instruments. When retrieving a process sample, hold the RFID tag near your TU5 online turbidimeter to collect the meter name, date, time and measured value. Once your sample is brought to the lab, simply hold the RFID tag near your benchtop turbidimeter to transfer the information. Then place the sample in the benchtop unit for measurement, and compare the measured values for instant validation. RFID operator ID tags also let personnel log into instruments with a swipe of their tag, and RFID labels on calibration standards let you pull up the Certificate of Analysis right on the meter.
Includes: StablCal® calibration set (10-, 20- and 600-NTU standards in sealed vials), power supply, dust cover, vial stand and user manual. 1-year warranty. For turbidimeter with RFID capabilities (stock # 93642), you must purchase RFID tags separately.
Note: EPA compliant as an Alternative Test Procedure. Discuss suitability of this instrument with your regulator.
Range: 0 to 700 NTU, FNU, TE/F or FTU;
0 to 100 mg/L; 0 to 175 EBC
Resolution: 0.0001 NTU
Accuracy: ±2% of reading or ±0.01 NTU (the larger value) from 0 to 40 NTU; ±10% of reading from 40 to 700 NTU
Sample size: 10 mL
MFR # DESCRIPTION STOCK #
LPV442.99.01012 TU5200 Turbidimeter 93641
LPV442.99.03012 TU5200 Turbidimeter with RFID Capability 93642
REPLACEMENT ITEMS & ACCESSORIES
LZV946 Sample Vials, Pack of 2 93643
LZV898 StablCal Calibration Set (10, 20 & 600 NTU) 93656
LZY835 StablCal Calibration Set w/ RFID (10, 20 & 600 NTU) 93657
LZY899 StablCal 20-NTU Standard 93658
LZY837 StablCal 20-NTU Standard with RFID 93659
LZY900 StablCal 600-NTU Standard 93644
LZY838 StablCal 600-NTU Standard with RFID 93645
LZY901 Glass Verification Rod, <0.1 NTU (Solid Secondary Standard) 93660
LZQ066 Operator RFID Tags, Pack of 2 86133
LZQ067 Sample RFID Tags/Stickers, Black, Pack of 3 93654
LZQ070 Sample RFID Tags/Stickers, Blue, Pack of 3 93655
LQV157.99.50002 Sipper Unit 93646
4397510 Sample Degassing Kit 32293
LZY903 Manual Vial Wiper Tool 93664
LZY945 Microfiber Cloth 93666
KIMWIPES® Disposable Wipes, 4-1/2" x 8-1/2", Box of 280 36989
Loading...