Hach TNTplus® COD Vial Test, TNTplus, High Range, 20 to 1500 mg/L, 25 Tests, TNT822

Description
- Color-coded packages make parameter and range recognition easy
- Pre-dosed reagents eliminate measurement and transfer steps
- Faster and easier than traditional methods
The TNTplus system gives you maximum accuracy, precision and repeatability, while minimizing the opportunity for errors. Vials feature freeze-dried reagent integrated into a sealed cap. A unique barcode on each vial is automatically read by Hach spectrophotometers to identify the appropriate method and take the measurement.
Each sample is measured 10 times around the vial’s circumference. The measurements are analyzed for outliers and then averaged.
EPA-compliant method. Some tests require sample pretreatment such as filtration, distillation or digestion to meet EPA testing requirements. Includes Truecal calibration data.
Note: Contains mercury. Dispose of according to local, state and federal regulations.
Shipping: Item may incur hazardous shipping charges.
- Method: 8000, Reactor Digestion
- EPA compliant: yes
- Range: 20 to 1500 mg/L,
- Sample size: 100 mL (with suspended solids): 2.0 mL (no suspended solids)
- Compatibility: Hach DR3900, DR6000, DR1900, DR2800, DR3800, DR5000
Product Information
- Item number
- 200740
- Brand Name
- Hach Company
- Catalog Page
- 753
- Net weight
- 0.8
- Condition
- New
- Special Savings
- Standard Pricing

Hach TNTplus® COD Vial Test, TNTplus, High Range, 20 to 1500 mg/L, 25 Tests, TNT822
- Item number
- 200740
- Brand Name
- Hach Company
- Catalog Page
- 753
- Net weight
- 0.8
- Condition
- New
- Special Savings
- Standard Pricing
- Color-coded packages make parameter and range recognition easy
- Pre-dosed reagents eliminate measurement and transfer steps
- Faster and easier than traditional methods
The TNTplus system gives you maximum accuracy, precision and repeatability, while minimizing the opportunity for errors. Vials feature freeze-dried reagent integrated into a sealed cap. A unique barcode on each vial is automatically read by Hach spectrophotometers to identify the appropriate method and take the measurement.
Each sample is measured 10 times around the vial’s circumference. The measurements are analyzed for outliers and then averaged.
EPA-compliant method. Some tests require sample pretreatment such as filtration, distillation or digestion to meet EPA testing requirements. Includes Truecal calibration data.
Note: Contains mercury. Dispose of according to local, state and federal regulations.
Shipping: Item may incur hazardous shipping charges.
- Method: 8000, Reactor Digestion
- EPA compliant: yes
- Range: 20 to 1500 mg/L,
- Sample size: 100 mL (with suspended solids): 2.0 mL (no suspended solids)
- Compatibility: Hach DR3900, DR6000, DR1900, DR2800, DR3800, DR5000